-40%
Inkbird ITC-1000 12V AC 10A temperature controller Thermostat Digital C/F On/Off
$ 8.44
- Description
- Size Guide
Description
ITC-1000 temperature controller12V
Main Function:
-
Fahrenheit and Celsius Display Can Be Choose
-
More User-friendly Operating
-
Switch Between Cooling and Heating Modes
-
Control the Temperature by Setting the Temperature Set Value and the Difference Value
-
Temperature Calibrating
-
Refrigerating control output delay protection
-
Alarm When Temperature Exceeds the Limit or When Sensor Error
Mounting dimension:
-Front Panel Size: 75(L)*34.5(W)mm
-Mounting Size: 71(L)*29(W)mm
-Product Size
:
75(L)*34.5(W)*85(D)mm
-Sensor Length: 2m (include the probe)
Technical Parameter:
-Temperature Measuring Range: -50
~
210
o
F / -50
o
C
-99
o
C
-Resolution: 0.1
o
F / 0.1
o
C
-Accuracy: ±1
o
F
(
-50
o
F -160
o
F
)
/ ±1
o
C
(
-50
o
C
-70
o
C
)
-Power Supply: 12 VDC 50Hz/60Hz
-Power Consumption: <3W
-Sensor: NTC Sensor
-Relay Contact Capacity: Cooling (10A/250VAC)/ Heating (10A/250VAC);
-Ambient Temperature: 0
o
C
-
60
o
C
-Storage Temperature:
-
30
o
C
-
75
o
C
-Relative Humidity: 20-85% (No Condensate)
Menu Instruction:
1.
When the set
temperature is
degrees Celsius (
C)
Code
Function
Set range
Default
Note
TS
Temperature Set Value
-50
~
99.9
o
C
10.0
o
C
DS
Difference Set Value
0.3
~
15
o
C
1.0
o
C
PT
Compressor Delay
0
~
10 minutes
3munites
CA
Temperature Calibration Value
-15
o
C
~
15
o
C
0
o
C
CF
Fahrenheit or Celsius Setting
C
2.
When the set temperature is degrees Fahrenheit (
F)
Code
Function
Set range
Default
Note
TS
Temperature Set Value
-50
~
210
o
F
50
o
F
Min. Unit 1
o
F
DS
Difference Set Value
1
~
30
o
F
3
o
F
PT
Compressor Delay
0
~
10 minutes
3 minutes
CA
Temperature Calibration Value
-15
~
15
o
F
0
o
F
CF
Fahrenheit or Celsius Setting
F
Note:
When CF value change, all the set values restore to default value.
Error Description
Sensor Error Alarm:
When
the temperature
sensor
circuit
is
short circuit
or
open circuit
, the controller starts sensor error mode and closes all running status, the buzzer alarm sounds, screen displays ER. Press any keys can cancel buzzer alarm, the system returns to the normal working status after error is cleared.
Over-temperature Alarm:
When the measuring temperature exceeds the temperature measuring range, the controller starts over-temperature error alarm mode
and closes all running status, the buzzer alarm sounds, screen displays HL. Press any keys can cancel buzzer alarm, the system returns to the normal working status after the temperature returns to measuring range.
Package included:
1 ×
ITC-1000F 12V Temperature
Controller
1 x NTC Sensor
1 x English Manual